Through bolt anchor, mechanical expansion anchor bolt. For use in cracked and non-cracked concrete. ETA Option 1 approved for structural applications.
| Article Code | Size | Washer Ø mm | Clamping Thickness mm |
|---|---|---|---|
| INSTALLATION DATA | |||||||
| SIZE | M8 | M10 | M12 | M16 | M20 | ||
| d0 | Nominal diameter of drill bit | [mm] | 8 | 10 | 12 | 16 | 20 |
| Tin | Installation torque moment | [Nm] | 15 | 40 | 60 | 100 | 200 |
| df≤ | Diameter of clearance hole in the fixture | [mm] | 9 | 12 | 14 | 18 | 22 |
| h1 | Minimum drill hole depth | [mm] | 60 | 75 | 85 | 105 | 125 |
| hnom | Installation depth | [mm] | 55 | 68 | 80 | 97 | 114 |
| hef | Effective embedment depth | [mm] | 48 | 60 | 70 | 85 | 100 |
| hmin | Minimum base material thickness | [mm] | 100 | 120 | 140 | 170 | 200 |
| tfix | Maximum thickness of fixture* | [mm] | L - 66 | L - 80 | L - 96 | L - 117 | L-138 |
| Scr,N | Critical spacing | [mm] | 144 | 180 | 210 | 255 | 300 |
| Ccr,N | Critical edge distance | [mm] | 72 | 90 | 105 | 128 | 150 |
| Smin | Minimum spacing | [mm] | 50 | 60 | 70 | 128 | 150 |
| Cmin | Minimum edge distance | [mm] | 50 | 60 | 70 | 128 | 150 |
| SW | Installation wrench size | [mm] | 13 | 17 | 19 | 24 | 30 |